60W Series DSA-60W
Universal Input A dapter Switching Power Supply
Features
*Meet CEC *Low Power Consumption
*Class I EMI *<750ua Leakage
*Class II EMI *<250ua Leakage
Applications
*Computer *Communication *Consumer
Safety Approvals(60950+60065)
*UL/CUL *BSMI *CB *PSE *T-License
*CCC *SAA/C-Tick *KA *GS
Safety Approvals(60335)
*UL/CUL *CB *GS(Only Class II for 12V,5A)
*T-License(Only Class II for 12V,5A) *SAA/C-Tick(Only Class II for 12V,5A)
Output Specifications
b=1/2/3,(1 means C14 AC inlet,2 means C8 AC inlet,3 means C6 AC inlet)
x=120—240,(120means output voltage is 12.0V)
y=3 digit number which represents the output voltage
A means Safety Approvals 60065 H means Safety Approvals 60335
MODEL INPUT Voltage OUTPUT
Range Frequancy Vdc Reg. A(max) W(max)
DSA-60W-12 bxy/A/H 100-240V 50/60Hz1.5A 12-14 ±5% 5 60
DSA-60W-16 bxy/A/H 100-240V 50/60Hz1.5A 14.1-19 ±5% 4.26 60
DSA-60W-20 bxy/A/H 100-240V 50/60Hz1.5A 19.1-24 ±5% 3.16 60
DSA-60W Characteristics
AC Input Voltage Operation Temperature
90 to 264 VAC 0 to 40℃
AC Input Frequancy: Storage Temperature
47 to 63 Hz -25 to +60℃
AC Input Current(Full Load) MTBF
1.5A MAX 50000-100000 by option
(full load,240V A C,25℃)
Leakage Current Emissions
Less than 250μA,(264V A C) Class 2 FCC Class B
Less than 750μA,(264V A C) Class 1 EN 55022 B,EN55013B,EN55014B
Dielectric Withstand(Hi-pot)
3000V(1500V)AC,1 min,10m A CLASS2(1)
Hold-up Time(Full Load) Immunity
5mS 120V A C 61000-4-2,Level 3
20mS 240V A C 61000-4-3,Level 2
Over current Protection 61000-4-4,Level 2
Short Circuit,Auto Restart 61000-4-5,Level 3
61000-4-6,Level 2
61000-4-11